A two-component adhesive is only as good as the package it arrives in. The cartridge is not a bottle: it is a volumetric metering device. Its two chambers, its pistons and its outlet together decide how much resin and how much hardener reach the static mixer on every stroke of the gun. When a bond cures soft, leaks in transit or blocks a nozzle, the cause is often the packaging rather than the chemistry.
This guide covers the four decisions that shape a cartridge order - mix ratio, capacity, material and the mechanical details most buyers never see - and closes with a specification routine and the questions worth asking before a sample is approved.
Every 2K cartridge is built around a fixed volumetric ratio: 1:1, 2:1, 3:1, 4:1 or 10:1. The ratio is not set by the gun or by the operator. It is set by the cross-sectional area of each chamber and by the fact that both pistons are advanced by the same plunger or push-rod pair. If chamber A has twice the area of chamber B, the cartridge delivers twice the volume, on every stroke, without adjustment.
That is also why the established industrial systems are organised by ratio and geometry rather than by brand name. The Sulzer Mixpac side-by-side C- and J-Systems cover 235 mL to 1500 mL in 1:1, 2:1, 3:1, 4:1 and 10:1, while its coaxial Q-System is built around 10:1 in 150, 310 and 380 mL. The choice between side-by-side and coaxial is really a choice about how to package a small B fraction: a 10:1 side-by-side cartridge needs a very slim hardener chamber, whereas a coaxial design places the hardener in an inner tube and keeps the outer body round and pressure-resistant.
One warning that costs real money: confirm whether your adhesive's ratio is specified by volume or by weight. Resin and hardener rarely share the same density, so a formulation quoted 1:1 by weight is not 1:1 by volume. Filling a volumetric cartridge to a weight-based ratio shifts the mix before the product has even left the plant.
Table 1. Standard mix ratios and how they are usually packaged
| Ratio | Chamber geometry | Typical chemistry | Common pack sizes |
| 1:1 | Two equal chambers, side by side | Epoxy, polyurethane, silicone, acrylic | 50-600 mL |
| 2:1 | A twice the section of B | Structural epoxy, PU | 50-400 mL |
| 3:1 | A three times the section of B | Construction and composite systems | 365-585 mL |
| 4:1 | A four times the section of B | Potting compounds, PU | 200-600 mL |
| 10:1 | Slim B chamber, or a coaxial inner tube | Chemical anchoring, low-hardener structural systems | 75-490 mL |
Capacity is usually chosen by habit, or by unit price. A more reliable method is to calculate the bead. For a triangular bead the cross-section is about 0.433 times the square of the width, so a 6 mm bead carries roughly 15.6 mm2 of adhesive - close to 15.6 mL per metre of run.
A 400 mL cartridge, allowing a few millilitres of purge, therefore gives about 24 to 25 m of 6 mm bead. The same arithmetic shows that a 50 mL cartridge is a repair tool at roughly 3 m, while a 600 mL cartridge is a production tool at roughly 38 m.
Capacity carries two hidden costs as well. The first is dead volume: at every cartridge change the mixer and outlet hold adhesive that will never be used, and that penalty is proportionally larger on small packs. The second is shelf life after opening. A capped cartridge can be stored and reused, but each opening exposes the material to air and moisture, so a two-week job does not always need the largest pack on the list.
Table 2. Approximate bead length per cartridge (6 mm triangular bead, before purge)
| Nominal capacity | Approx. 6 mm bead | Typical use | Usual dispensing |
| 50 mL | ~3 m | Repair, sample kits, small assembly | Manual |
| 75 mL | ~4.5 m | Precision assembly, small batches | Manual |
| 200 mL | ~12 m | General bonding, electronics | Manual or pneumatic |
| 250 mL | ~16 m | Anchoring and 10:1 structural work | Manual or pneumatic |
| 400 mL | ~25 m | Structural bonding, mid-volume lines | Manual or pneumatic |
| 490 mL | ~31 m | High-ratio structural and anchoring | Pneumatic |
| 600 mL | ~38 m | Production bonding, long runs | Pneumatic |
| 1500 mL | ~95 m | Bulk dispensing, meter-mix feed | Pneumatic or meter-mix |
Three thermoplastics dominate 2K cartridge barrels, and the difference appears under pressure rather than on a datasheet.
Table 3. Barrel material selection
| Material | Stiffness | Solvent resistance | Moisture sensitivity | Best fit |
| PP | Moderate | Good for common epoxy, PU and silicone | Low | 1:1, 2:1 and 3:1 general purpose |
| PBT | High | Good | Low | 10:1 and other slim-chamber, high-pressure work |
| PA | Moderate to high | Very good | High (hygroscopic) | Solvent-rich fills, long shelf-life barrier |
Two cartridges can look identical in a catalogue and behave completely differently in the field. Four features account for most of that gap.
1. Read the TDS and write down the ratio, and whether it is expressed by volume or by weight.
2. Screen the chemistry against the barrel material: solvents, acidity, amine content and filler loading all matter.
3. Calculate total volume from bead cross-section times run length, then add 5 to 10 percent for purge.
4. Set the pressure class from the dispensing method; manual guns are gentle, pneumatic guns and meter-mix lines are not.
5. Lock the outlet interface to the mixer family already in stock, or plan to change both together.
6. Check the filling and logistics side: nozzle or plug configuration, case pack, pallet pattern and container utilisation.
JAPI moulds PP, PBT and PA cartridges from 30 mL to 1500 mL in 1:1, 2:1, 3:1, 4:1 and 10:1, and supplies the matching static mixers as one system, which is the simplest way to avoid an interface mismatch. For a closer look at how the gun side of the system works, see our article on how adhesive dispensing guns work.
Specifying a new 2K pack? Send us the adhesive TDS, the target fill volume and the gun you intend to use. JAPI will match cartridge, piston and mixer as one set, and send filled samples for a line trial.
A two-component adhesive is only as good as the package it arrives in. The cartridge is not a bottle: it is a volumetric metering device. Its two chambers, its pistons and its outlet together decide how much resin and how much hardener reach the static mixer on every stroke of the gun. When a bond cures soft, leaks in transit or blocks a nozzle, the cause is often the packaging rather than the chemistry.
This guide covers the four decisions that shape a cartridge order - mix ratio, capacity, material and the mechanical details most buyers never see - and closes with a specification routine and the questions worth asking before a sample is approved.
Every 2K cartridge is built around a fixed volumetric ratio: 1:1, 2:1, 3:1, 4:1 or 10:1. The ratio is not set by the gun or by the operator. It is set by the cross-sectional area of each chamber and by the fact that both pistons are advanced by the same plunger or push-rod pair. If chamber A has twice the area of chamber B, the cartridge delivers twice the volume, on every stroke, without adjustment.
That is also why the established industrial systems are organised by ratio and geometry rather than by brand name. The Sulzer Mixpac side-by-side C- and J-Systems cover 235 mL to 1500 mL in 1:1, 2:1, 3:1, 4:1 and 10:1, while its coaxial Q-System is built around 10:1 in 150, 310 and 380 mL. The choice between side-by-side and coaxial is really a choice about how to package a small B fraction: a 10:1 side-by-side cartridge needs a very slim hardener chamber, whereas a coaxial design places the hardener in an inner tube and keeps the outer body round and pressure-resistant.
One warning that costs real money: confirm whether your adhesive's ratio is specified by volume or by weight. Resin and hardener rarely share the same density, so a formulation quoted 1:1 by weight is not 1:1 by volume. Filling a volumetric cartridge to a weight-based ratio shifts the mix before the product has even left the plant.
Table 1. Standard mix ratios and how they are usually packaged
| Ratio | Chamber geometry | Typical chemistry | Common pack sizes |
| 1:1 | Two equal chambers, side by side | Epoxy, polyurethane, silicone, acrylic | 50-600 mL |
| 2:1 | A twice the section of B | Structural epoxy, PU | 50-400 mL |
| 3:1 | A three times the section of B | Construction and composite systems | 365-585 mL |
| 4:1 | A four times the section of B | Potting compounds, PU | 200-600 mL |
| 10:1 | Slim B chamber, or a coaxial inner tube | Chemical anchoring, low-hardener structural systems | 75-490 mL |
Capacity is usually chosen by habit, or by unit price. A more reliable method is to calculate the bead. For a triangular bead the cross-section is about 0.433 times the square of the width, so a 6 mm bead carries roughly 15.6 mm2 of adhesive - close to 15.6 mL per metre of run.
A 400 mL cartridge, allowing a few millilitres of purge, therefore gives about 24 to 25 m of 6 mm bead. The same arithmetic shows that a 50 mL cartridge is a repair tool at roughly 3 m, while a 600 mL cartridge is a production tool at roughly 38 m.
Capacity carries two hidden costs as well. The first is dead volume: at every cartridge change the mixer and outlet hold adhesive that will never be used, and that penalty is proportionally larger on small packs. The second is shelf life after opening. A capped cartridge can be stored and reused, but each opening exposes the material to air and moisture, so a two-week job does not always need the largest pack on the list.
Table 2. Approximate bead length per cartridge (6 mm triangular bead, before purge)
| Nominal capacity | Approx. 6 mm bead | Typical use | Usual dispensing |
| 50 mL | ~3 m | Repair, sample kits, small assembly | Manual |
| 75 mL | ~4.5 m | Precision assembly, small batches | Manual |
| 200 mL | ~12 m | General bonding, electronics | Manual or pneumatic |
| 250 mL | ~16 m | Anchoring and 10:1 structural work | Manual or pneumatic |
| 400 mL | ~25 m | Structural bonding, mid-volume lines | Manual or pneumatic |
| 490 mL | ~31 m | High-ratio structural and anchoring | Pneumatic |
| 600 mL | ~38 m | Production bonding, long runs | Pneumatic |
| 1500 mL | ~95 m | Bulk dispensing, meter-mix feed | Pneumatic or meter-mix |
Three thermoplastics dominate 2K cartridge barrels, and the difference appears under pressure rather than on a datasheet.
Table 3. Barrel material selection
| Material | Stiffness | Solvent resistance | Moisture sensitivity | Best fit |
| PP | Moderate | Good for common epoxy, PU and silicone | Low | 1:1, 2:1 and 3:1 general purpose |
| PBT | High | Good | Low | 10:1 and other slim-chamber, high-pressure work |
| PA | Moderate to high | Very good | High (hygroscopic) | Solvent-rich fills, long shelf-life barrier |
Two cartridges can look identical in a catalogue and behave completely differently in the field. Four features account for most of that gap.
1. Read the TDS and write down the ratio, and whether it is expressed by volume or by weight.
2. Screen the chemistry against the barrel material: solvents, acidity, amine content and filler loading all matter.
3. Calculate total volume from bead cross-section times run length, then add 5 to 10 percent for purge.
4. Set the pressure class from the dispensing method; manual guns are gentle, pneumatic guns and meter-mix lines are not.
5. Lock the outlet interface to the mixer family already in stock, or plan to change both together.
6. Check the filling and logistics side: nozzle or plug configuration, case pack, pallet pattern and container utilisation.
JAPI moulds PP, PBT and PA cartridges from 30 mL to 1500 mL in 1:1, 2:1, 3:1, 4:1 and 10:1, and supplies the matching static mixers as one system, which is the simplest way to avoid an interface mismatch. For a closer look at how the gun side of the system works, see our article on how adhesive dispensing guns work.
Specifying a new 2K pack? Send us the adhesive TDS, the target fill volume and the gun you intend to use. JAPI will match cartridge, piston and mixer as one set, and send filled samples for a line trial.